prepFAST 2 Autodilution System

The Next Step in Automation

prepFAST 2 is the ultimate sample/standard autodilution system, automatically precise and accurate inline dilutions. Capable of up to 400x dilution, the prepFAST 2 is the fastest, simplest way to ensure high quality data in every run.


Calibrate using 1 stock standard

Calibrate using 1 stock standard

Accurate results at any dilution (CRM 1643e)
3 4 5 6 7 8

Features:

  • Autodilution – Automatically dilute samples with the click of a button
  • Autocalibration – Create instrument calibration curves from a single stock standard
  • Auto QC Dilution – Automatically re-run and dilute samples that fail sample QC for concentration or internal standard recovery
  • Automatic IS Addition – Automatic syringe addition of internal standard to every sample just before analysis

Benefits:

  • Eliminate offline dilution
  • Reduce reagent usage
  • Improve data quality
  • Enhance laboratory workflow and productivity
  • Excellent return on investment

How It Works

The prepFAST 2 automatically dilutes and analyzes samples using the following steps:

  • Load – sample is loaded from autosampler into dilution valve
  • Dilute – Sample, Diluent, and Internal Standard are rapidly mixed into the injection valve
  • Analysis – Sample anlyzed on ICP/ICP-MS, dilution loop is cleaned simultaneously
  • Rinse – ICP/ICP-MS and injection loop are rinsed before next sample

prepFAST Autodilution Animation

Applications

prepFAST 2 can be used anywhere instrument calibration and sample dilution are required. Common applications for the prepFAST 2 include:

Sizes and Specifications

The prepFAST 2 comes with 4 optional autosampler sizes. The autosampler size dictates the number or size of vials that can be analyzed at a time.

  Autosampler Model
  2DX 4DX 8DX 14DX
Standard Rack Capacity 2 4 8 14
Micro Rack Capacity 4 6    
Length - A - (mm) 542 770 578 1168
Width - B - (mm) 346 346 552 615
Height - C - (mm) 1300 1300 1405 1405
Height w/ Optional Enclosure - D - (mm) 1312 1312 1417 1417
Power Requirements 100-240 VAC ± 10%, 50-60 Hz, 10A
PC Communication Requirements 2 USB Communication Ports
Exhuast Requirements (Optional) 40 CFM
Sizes and Specifications